tCO
Thermo King
Critical

ECM Internal Temperature Exceeds Limit (DSR)

Electronic Control Module internal temperature exceeds its maximum allowed limit.

Possible causes

  • High ambient temperature near ECM
  • Failed ECM cooling
  • ECM mounted near heat source
  • Internal fault in ECM

Recommended actions

  • Allow controller to cool
  • Verify mounting and ventilation
  • Inspect for nearby heat sources
  • Replace ECM if fault persists