Remote Return Air Temperature Sensor Fault (DSR)

Fault in the remote return air temperature sensor on the DSR system.

Possible causes

  • Remote sensor cable damaged
  • Open or short in sensor circuit
  • Failed remote sensor
  • Loose connector at controller

Recommended actions

  • Inspect remote sensor cable
  • Check sensor resistance against spec
  • Replace sensor if needed
  • Verify connector integrity