546
Thermo King
Warning

Battery Charger Operating Bulk Voltage Out of Range

The charging voltage during the 'Bulk' stage is outside the normal operating range.

Possible causes

  • Extremely discharged or damaged battery
  • High resistance in battery connections
  • Charger unable to maintain constant current
  • Battery temperature influencing the charge curve

Recommended actions

  • Charge battery externally to see if it recovers
  • Clean all power and ground connection points
  • Check battery temperature sensor
  • Verify alternator/charger capacity