545
Thermo King
Warning

Battery Charger Output Voltage Exceeded Limit

The battery charger output voltage exceeded the maximum safety limit.

Possible causes

  • Internal charger regulator failure
  • Sudden battery disconnection while charging
  • Incorrect battery type configuration
  • Charger voltage sensor failure

Recommended actions

  • Measure output voltage with a calibrated multimeter
  • Ensure battery cables are secure
  • Check controller settings (Lead-acid vs AGM)
  • Replace charger if voltage exceeds 15V-16V on nominal 12V