528
Thermo King
Warning

Failed J1939 CAN Comm Base Controller/Charger

J1939 CAN communication failure between the base controller and the battery charger.

Possible causes

  • Damaged CAN network cable between components
  • Missing or damaged CAN termination resistor
  • Loss of power to the charger
  • Internal communication failure in the charger

Recommended actions

  • Check continuity of the CAN wiring harness
  • Ensure the charger has 12V power supply
  • Measure CAN network resistance (should be ~60 ohms)
  • Check connectors for bent pins or moisture