525
Thermo King
Warning

Generator Frequency Range Fault

The generator output frequency is outside the allowed range (Hz).

Possible causes

  • Incorrect engine RPM (too high or too low)
  • Malfunctioning engine governor
  • Speed sensor failure
  • Clogged fuel filter causing instability

Recommended actions

  • Check and adjust engine RPM according to manual
  • Replace fuel filters
  • Inspect speed solenoid or actuator
  • Check frequency/RPM sensor