522
Thermo King
Warning

Battery Temperature Sensor Alarm

Battery temperature sensor reports out of range readings or is disconnected.

Possible causes

  • Defective temperature sensor
  • Broken or disconnected sensor wire
  • Actual battery overheating from overcharging
  • Corroded sensor connector

Recommended actions

  • Verify physical connection of sensor on battery post
  • Measure sensor resistance (NTC/PTC)
  • Check if battery is physically hot
  • Replace sensor if reading is erroneous