52
Thermo King
Warning

Check Heat Circuit (Zone)

System detected a problem in the components generating heat in the zone.

Possible causes

  • Burnt heat solenoid valve
  • Damaged electric heating elements (if applicable)
  • Open control circuit
  • Air damper failure

Recommended actions

  • Test heat solenoid via manual diagnosis
  • Verify heating circuit fuses
  • Measure circuit continuity
  • Check hot gas valve operation