516
Thermo King
Critical

I/O Controller to Application Controller Com Failure

Critical communication failure between I/O controller and application controller.

Possible causes

  • Poor contact in ribbon cables or data jumpers
  • Power failure on one of the electronic boards
  • Severe electrical interference
  • Defective application controller

Recommended actions

  • Power down unit and reseat all board connectors
  • Measure supply voltages on both controllers
  • Verify ground wires and communication shielding
  • Replace controller if error persists after reboot

Can't find your code? Talk to an expert