515
Thermo King
Warning

Minimum ETV Discharge Superheat Temp (Scroll)

ETV controlled discharge superheat is at the minimum thermal limit.

Possible causes

  • Liquid refrigerant returning to compressor
  • Expansion valve overfeeding
  • Discharge temperature sensor failure
  • Excessive oil carryover into the circuit

Recommended actions

  • Verify superheat settings
  • Check compressor discharge temperature sensor
  • Inspect ETV valve and pressure sensor
  • Ensure TXV bulb is securely fastened