514
Thermo King
Warning

Low Compressor Discharge Pressure (Scroll Only)

Scroll compressor discharge pressure too low during operation.

Possible causes

  • Low refrigerant charge in the system
  • Worn or internally damaged scroll compressor
  • Failed discharge check valves
  • Extremely low ambient temperature

Recommended actions

  • Apply refrigerant charge as needed
  • Perform compressor efficiency test
  • Inspect bypass and check valves
  • Confirm condenser fans are not over-spinning