40
Thermo King
Warning

Check High Speed Circuit

The microprocessor detected a failure in the circuit that activates engine high speed.

Possible causes

  • Defective speed solenoid
  • Failed high speed relay
  • Obstructed throttle mechanical linkage
  • Wiring failure between controller and solenoid

Recommended actions

  • Test speed solenoid with external power
  • Clean and lubricate throttle linkage
  • Check high speed relay on the board
  • Inspect control fuses