32
Thermo King
Critical

Refrigeration Capacity Low (Zone)

The unit or zone is not reaching the expected cooling capacity and has been stopped for safety.

Possible causes

  • Refrigerant leak
  • Low compressor efficiency or internal damage
  • Expansion valve restriction
  • Evaporator or condenser coil failure

Recommended actions

  • Check refrigerant levels in the sight glass
  • Check suction and discharge pressures
  • Review coil cleanliness
  • Inspect solenoid valve operation