124
Thermo King
Critical

Check Evap Coil Outlet Temp Sensor (CR)

Failure in the evaporator coil outlet temperature sensor (CR).

Possible causes

  • Outlet sensor open or shorted
  • Loose connection at terminal board
  • Sensor out of calibration
  • Interruption in zone wiring

Recommended actions

  • Check connections at the evaporator
  • Measure sensor resistance
  • Verify wiring is not exposed to elements
  • Replace the coil outlet sensor