120
Thermo King
Critical

Check Alternator Excite Circuit

Fault detected in the alternator excitation circuit; the battery may not be charging.

Possible causes

  • Worn alternator brushes
  • Defective voltage regulator
  • Loose or broken alternator belt
  • Excite circuit (2A wire) open

Recommended actions

  • Check alternator belt tension
  • Measure voltage with engine running (should be 13-14V)
  • Inspect alternator wiring
  • Replace alternator if not generating charge