115
Thermo King
Critical

Check High Pressure Cut Out Switch

Fault in the High Pressure Cut Out (HPCO) switch or its circuit.

Possible causes

  • Defective HPCO switch
  • Dangerously high discharge pressure
  • HPCO switch wiring disconnected or shorted
  • Inoperative condenser fan

Recommended actions

  • Check discharge pressures with gauges
  • Check HPCO switch continuity
  • Clean condenser and verify airflow
  • Replace switch if it trips at normal pressures