115
Thermo King
Critical
Check High Pressure Cut Out Switch
Fault in the High Pressure Cut Out (HPCO) switch or its circuit.
Possible causes
- Defective HPCO switch
- Dangerously high discharge pressure
- HPCO switch wiring disconnected or shorted
- Inoperative condenser fan
Recommended actions
- Check discharge pressures with gauges
- Check HPCO switch continuity
- Clean condenser and verify airflow
- Replace switch if it trips at normal pressures
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.
Other Thermo King codes
Need a professional diagnosis?
Low Temp Service — refrigeration experts in Florida.