104
Thermo King
Warning
Check Remote Fan Speed (Zone)
The controller cannot detect or maintain the required speed for the remote zone fans.
Possible causes
- Loose or broken fan belts
- Remote fan motor with worn brushes or electrical failure
- Speed sensor (tachometer) failure
- Voltage drop to remote evaporators
Recommended actions
- Physically inspect remote fans
- Check motor condition and connections
- Verify voltage at motor terminals
- Clear codes and test in high speed mode