102
Thermo King
Critical

Low Evaporator Coil Temperature (CR)

Evaporator coil temperature is dangerously low, which may lead to icing or freezing.

Possible causes

  • Insufficient airflow due to dirty coil or ice buildup
  • Low refrigerant charge
  • Evaporator fan failure
  • Incorrectly adjusted expansion valve

Recommended actions

  • Perform a manual defrost cycle immediately
  • Verify coil is not obstructed by debris
  • Inspect fan operation and speed
  • Check system suction pressures