10
Thermo King
Critical

High Discharge Pressure (or Temperature)

The compressor discharge pressure or temperature has exceeded safety limits.

Possible causes

  • Dirty or obstructed condenser coil
  • Condenser fan not working
  • Refrigerant overcharge or non-condensable gases

Recommended actions

  • Clean condenser coil with pressurized water
  • Verify condenser fan operation
  • Check high-pressure transducer and pressure switch