High Evaporator Temperature (Zone)

An excessively high evaporator temperature has been detected.

Possible causes

  • Expansion valve (TXV) blocked or failing
  • Low refrigerant charge in the system
  • Burned-out evaporator fan motors

Recommended actions

  • Check suction and discharge pressures
  • Check fan rotation and airflow
  • Inspect filter drier and check for leaks