P14000
Carrier Transicold
Warning

C2 Chk Evap1 Superheat

Superheat out of range in evaporator 1 of compartment 2.

Possible causes

  • Electronic expansion valve (EEV) failure
  • Low refrigerant charge
  • Erratic suction pressure or temperature sensor

Recommended actions

  • Monitor EEV opening on the microprocessor
  • Check refrigerant charge
  • Evaluate involved temperature and pressure sensors
  • Replace EEV or sensor based on diagnosis