P00216
Carrier Transicold
Critical

Check Damper – Not Closing

The defrost damper does not close properly, preventing proper airflow during refrigeration.

Possible causes

  • Obstruction by ice or debris
  • Defective damper solenoid
  • Damaged or bent mechanical linkage
  • Wiring or electrical connection failure

Recommended actions

  • Visually inspect damper for ice or damage
  • Check solenoid operation via component test
  • Lubricate or repair mechanical linkages
  • Verify continuity in damper wire harness