P00201
Carrier Transicold
Warning

Check UL2 Cylinders

Error detected in the cylinder unloading of the second stage (UL2).

Possible causes

  • UL2 coil electrical failure
  • Obstructed oil passages
  • Wear on the unloader piston

Recommended actions

  • Check voltage at UL2 during Pretrip
  • Inspect solenoid for burrs
  • Perform manual functional test