P00184
Carrier Transicold
Critical

C2 Check Evap Fan Motor

Fault detected in the compartment 2 evaporator fan motor.

Possible causes

  • Burned motor or seized bearings
  • Failed start capacitor
  • Open fan circuit breaker or fuse

Recommended actions

  • Check for free rotation of the fan blades
  • Measure motor supply voltage
  • Verify capacitor condition and thermal protectors