P00172
Carrier Transicold
Warning
Check Bypass
Generic or flow failure in the bypass valve detected by pressure sensors.
Possible causes
- Defective bypass coil
- Failed internal compressor bypass
- Pressure sensor misinterpretation
Recommended actions
- Validate bypass valve activation
- Verify pressure drop when bypass opens
- Inspect control wiring
Can't find your code? Talk to an expert
$150
One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.
Other Carrier Transicold codes
Need a professional diagnosis?
Low Temp Service — refrigeration experts in Florida.