P00146
Carrier Transicold
Critical

C2 Check Heater 1 Circuit

Failure in compartment 2 (C2) heater 1 circuit.

Possible causes

  • Open electrical resistance
  • Defective heating contactor
  • Blown AC load fuse

Recommended actions

  • Check continuity of the heaters
  • Check C2 evaporator contactor K1/K2
  • Measure voltage at heater terminals

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?

Low Temp Service — refrigeration experts in Florida.