26108
Carrier Transicold
Warning

Rack Position Abnormal ENCU

The position of the fuel rack or actuator does not match expected values.

Possible causes

  • Dirty or stuck injection actuator
  • Weakened return spring
  • Obstructed linkage
  • Defective internal position sensor

Recommended actions

  • Inspect injection linkage
  • Clean fuel solenoid/actuator
  • Reset ENCU learning parameters
  • Replace fuel actuator

Can't find your code? Talk to an expert