25400
Carrier Transicold
Critical

No Comm From Micro to STP4

Communication failure between the microprocessor and stepper motor module 4 (STP4).

Possible causes

  • Defective CAN connection to STP4
  • Lack of power at the module
  • Damaged STP4 control board
  • Severe electrical noise

Recommended actions

  • Verify communication network wiring
  • Confirm 12V power at the module
  • Restart microprocessor
  • Test with new STP4 module

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?