25202
Carrier Transicold
Warning

Check Input Voltage STP2

Supply voltage out of range detected at the STP2 module.

Possible causes

  • Low battery voltage
  • Corroded connectors increasing resistance
  • Excessive load from other peripherals
  • System regulator failure

Recommended actions

  • Charge or replace battery if weak
  • Check for voltage drop on the power bus
  • Clean and retighten terminals
  • Test engine charging system