25102
Carrier Transicold
Warning

Check Input Voltage STP1

Incorrect or unstable input voltage detected at the STP1 module.

Possible causes

  • Loose or corroded battery connections
  • Alternator with defective diode
  • Power relay failing
  • Excessive voltage drop in harness

Recommended actions

  • Verify and tighten battery terminals
  • Measure voltage under load at STP1 module
  • Check status of control power relays
  • Clean ground points of the control unit