25101
Carrier Transicold
Warning

Over Current STP1

Overcurrent detected in the stepper motor 1 (STP1) circuit.

Possible causes

  • Mechanical valve stuck or blocked
  • Short circuit in stepper motor coil
  • Internal moisture in valve motor
  • Damaged wiring rubbing against chassis

Recommended actions

  • Measure valve coil resistance
  • Inspect STP1 motor wires for damage
  • Attempt unit reset to recalibrate
  • Replace stepper motor or valve if stuck

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?

Low Temp Service — refrigeration experts in Florida.

Contact us