24400
Carrier Transicold
Critical

No Comm From Micro to CCB4

Loss of communication between the main microprocessor and the CCB4 board.

Possible causes

  • Damaged or disconnected CAN bus cable
  • Lack of power to the CCB4 board
  • Blown fuse
  • Internal failure of the CCB4 board

Recommended actions

  • Verify system power fuses
  • Check CAN bus wiring integrity
  • Measure input voltage at CCB4
  • Restart microprocessor and verify reconnection