24301
Carrier Transicold
Warning

Sensor Input Voltage Low CCB3

The microprocessor detected sensor input voltage below the threshold on the CCB3 board.

Possible causes

  • Short circuit in Compartment 3 sensors
  • Excessive moisture in the C3 control box
  • Low voltage output from the main microprocessor

Recommended actions

  • Check sensor wiring in evaporator 3
  • Clean and dry the CCB3 board
  • Measure regulator output voltage
  • Replace defective sensor or board