24300
Carrier Transicold
Critical

No Comm From Micro to CCB3

No communication with Compartment Control Board 3 (CCB3).

Possible causes

  • Harness disconnection at compartment 3
  • Lack of power at C3 module
  • Internal failure of CCB3 card

Recommended actions

  • Verify wiring continuity to compartment 3
  • Check power supply and C3 fuse
  • Test for CAN signal at the connector
  • Replace CCB3 card if inoperative