24200
Carrier Transicold
Critical
No Comm From Micro to CCB2
Communication failure with Compartment Control Board 2 (CCB2).
Possible causes
- Damaged CAN bus wiring to C2
- CCB2 board without power supply
- Electronic failure in CCB2
Recommended actions
- Inspect wiring harness going to evaporator 2
- Verify voltage at CCB2 board
- Check connectors for corrosion
- Replace CCB2 board if necessary