24200
Carrier Transicold
Critical

No Comm From Micro to CCB2

Communication failure with Compartment Control Board 2 (CCB2).

Possible causes

  • Damaged CAN bus wiring to C2
  • CCB2 board without power supply
  • Electronic failure in CCB2

Recommended actions

  • Inspect wiring harness going to evaporator 2
  • Verify voltage at CCB2 board
  • Check connectors for corrosion
  • Replace CCB2 board if necessary