24100
Carrier Transicold
Critical

No Comm From Micro to CCB1

No communication between the microprocessor and Compartment Control Board 1 (CCB1).

Possible causes

  • Interrupted CAN bus cable to CCB1
  • Power failure on CCB1 board
  • Internal CCB1 hardware failure

Recommended actions

  • Check signal connectors on evaporator 1 board
  • Verify fuses supplying the CCB1 controller
  • Measure data line resistance
  • Replace CCB1 board