22103
Carrier Transicold
Critical

Output Lost Configuration

The output configuration for Input Board 1 has been lost or is invalid.

Possible causes

  • Software error or corrupt firmware
  • Damaged board EEPROM memory
  • Incorrect configuration upload

Recommended actions

  • Attempt to factory reset the microprocessor
  • Update APX unit software
  • Manually reconfigure parameters if possible
  • Replace INPBD1 board if it does not hold configuration