22101
Carrier Transicold
Warning

Sensor Input Voltage Low INP1

The input voltage for sensors on the INP1 board is too low.

Possible causes

  • Weak unit battery
  • Short circuit in a powered sensor
  • Faulty board voltage regulator

Recommended actions

  • Check battery and alternator status
  • Disconnect sensors one by one to find short circuits
  • Measure reference voltage on the INP1 board
  • Replace board if internal voltage is insufficient