22100
Carrier Transicold
Critical

No Comm From Micro to INPBD1

Communication failure between the microprocessor and the input board 1 (INPBD1).

Possible causes

  • Connection failure in the CAN harness
  • Loss of power to the INPBD1 board
  • Internal failure of the input board

Recommended actions

  • Check INPBD1 board data connector
  • Measure supply voltage (12V) on the board
  • Verify CAN bus terminating resistors
  • Replace input board if powered but not communicating

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.