07003
Carrier Transicold
Warning

C2 Chk Evap Temp Sensor

Indicates a problem with the evaporator temperature sensor in compartment 2.

Possible causes

  • Defective evaporator sensor
  • Ice buildup interfering with the reading
  • Sensor wiring harness failure

Recommended actions

  • Ensure sensor is properly positioned on the coil
  • Check resistance of sensor C2
  • Inspect physical condition of the wiring
  • Restart the unit and monitor reactivation

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.