07002
Carrier Transicold
Warning

C3 Chk Supply Air Sensor

Fault in the supply air sensor for compartment 3.

Possible causes

  • Open or shorted supply air sensor
  • Corrosion on connector terminals
  • Electromagnetic interference in the wiring

Recommended actions

  • Visually inspect C3 sensor wiring
  • Test sensor resistance (Ohms) against temperature
  • Clean and tighten connector contacts
  • Replace sensor if out of tolerance