07001
Carrier Transicold
Warning

Economizer Press Sensor

The microprocessor detected an out-of-range reading or a failure in the economizer pressure sensor.

Possible causes

  • Defective pressure sensor
  • Damaged wiring or connectors
  • Microprocessor input port failure

Recommended actions

  • Check harness connection to the sensor
  • Measure sensor supply voltage and signal
  • Compare manual gauge reading with sensor reading
  • Replace the sensor if values are incorrect