05025
Carrier Transicold
Critical
Check Standby Contactor
Additional error in the Standby contactor control circuit.
Possible causes
- Voltage feedback error
- Stuck main contacts
- Controller not detecting closure
Recommended actions
- Verify auxiliary contacts
- Check voltage arrival at motor
- Replace defective contactor