04002
Carrier Transicold
Warning

High Economizer Superheat

High superheat at the economizer; reduced cooling efficiency.

Possible causes

  • Obstructed Economizer Expansion Valve (EEV)
  • Low refrigerant level
  • Out-of-calibration economizer temperature sensor
  • Partially clogged filter drier

Recommended actions

  • Check refrigerant level in sight glass
  • Check economizer valve operation
  • Verify inlet/outlet temperature sensors
  • Clean or replace expansion valve if necessary