03000
Carrier Transicold
Critical

Motor Overload 1

Overload detected in the electric motor or fan motor 1.

Possible causes

  • Motor seized or obstructed
  • Short circuit in motor windings
  • Thermal protector activated by excessive heat
  • Motor bearing failure

Recommended actions

  • Verify motor rotates freely manually
  • Measure winding resistance and insulation
  • Check amperage draw
  • Review contactor status and connections

Can't find your code? Talk to an expert

$150

One-on-one phone session with a Low Temp refrigeration tech. Emergency temporary assistance only.

Have a question? Ask the community

Thousands of refrigeration mechanics read and answer for free. Post your case in under 1 minute.

Need a professional diagnosis?