00255
Carrier Transicold
Critical
Microprocessor Error
Generic internal microprocessor error; self-diagnostic failure.
Possible causes
- Checksum error
- Overheated or defective processor
- Voltage spike in the electrical system
Recommended actions
- Perform a cold start (disconnect battery)
- Check power supply and grounds
- Load the latest software
- Replace the control module if error persists