00133
Carrier Transicold
Warning
Check Remote Temp Sensor 1
Signal error in remote temperature sensor number 1.
Possible causes
- Remote sensor damaged by cargo loading
- Severed wiring between compartments
- Data bus addressing error
Recommended actions
- Inspect for physical damage in the remote compartment
- Verify signal wire continuity
- Restart APX microprocessor