00096
Carrier Transicold
Critical

Check GENCONR Relay Coil

Failure in the GENCONR relay coil (Generator Contactor).

Possible causes

  • Open power contactor coil
  • Generator exciter problem
  • Loose high-vibration connections

Recommended actions

  • Verify generator output
  • Tighten terminals on the GENCONR contactor
  • Replace relay if coil has no continuity