00086
Carrier Transicold
Warning

Check UL2 Circuit

Electrical failure detected in the Compressor Unloader 2 (UL2) circuit.

Possible causes

  • Burned out UL2 coil
  • Solenoid connector with bent pins
  • Short circuit to ground in wiring
  • Failed internal controller component

Recommended actions

  • Check unloader 2 coil ohms
  • Clean and reseat UL2 connector
  • Test voltage output from controller
  • Trace wiring for potential abrasions