00082
Carrier Transicold
Info

Check Remote Out of Range Light

The microprocessor detects an issue with the remote "Out of Range" indicator light.

Possible causes

  • Burned out remote bulb or LED
  • Broken remote light wiring
  • Poor ground on trailer structure
  • Damaged controller output pin

Recommended actions

  • Visually inspect remote light status
  • Verify signal wire continuity
  • Confirm common ground connection
  • Run light test from controller